Advertising
- Honeywell Econoswitch 7 Day User Manual Free
- Honeywell Econoswitch 7 Day User Manual Instructions
- Honeywell Econoswitch 7 Day User Manual Download
- Honeywell Econoswitch 7 Day User Manual Online
- Honeywell Econoswitch 7 Day User Manual Pdf
Honeywell EconoSwitch™ 1-Pole Programmable wall switch in white color, is rated at 120-Volt AC. It has contact rating of 2400-Watts. It has timing range of 7 days. This switch is suitable for use with incandescent, halogen and fluorescent lights. Get free shipping on your qualifying orders of Honeywell® ECONOSwitch® 7 Day. Get free shipping on your qualifying orders of Honeywell® ECONOSwitch® 7 Day Programmable Light Switch Timer, White. A program can apply to a single day or repeat every day, for each day of the week, the user can choose: Sunset /sunrise. Indicates the time and day Press this button to display today’s sunrise time. Press this button to display today’s sunset time. Setup Menus 5. Press the main button for 3 seconds to enter the setup menus. Refer to (3 sec.) the menu flowchart sheet on how to navigate the menus. RPLS740B/RPLS741B User guide 7-day Solar Programmable Wall Switch.
RPLS740B/RPLS741B
1/8
The RPLS740B/RPLS741B programmable wall switch has been designed to control lights and motors:
Cut power at the circuit breaker to avoid electric shock.
Remove the existing switch.
Install the new switch (see the appropriate section below).
Apply power at the circuit breaker.
The RPLS740B/RPLS741B will turn the lights on at sunset and turn them off at 11:00 pm by default. If these
settings are appropriate for you, you only need to set the time and date (see shaded zone in the menu
flowchart sheet). If the switch’s sunset time does not correspond to the actual sunset time, see sections 5.3.3
and 5.3.4.
settings are appropriate for you, you only need to set the time and date (see shaded zone in the menu
flowchart sheet). If the switch’s sunset time does not correspond to the actual sunset time, see sections 5.3.3
and 5.3.4.
5.1
Mode Menu
You can use the Mode menu to select one of the three modes of operation (see sections 5.1.1 to 5.1.3).
5.1.1 Manual Mode
In Manual mode, the RPLS740B/RPLS741B operates like a regular switch. To turn the
lights on or off, briefly press the main button. The icon appears when the switch is in
Manual mode.
lights on or off, briefly press the main button. The icon appears when the switch is in
Manual mode.
5.1.2 Automatic Mode
In Automatic mode, the RPLS740B/RPLS741B turns the lights on or off according to the
set programs (see Section 5.4). The
set programs (see Section 5.4). The
icon as well as the current program number are
displayed.
5.1.3 Random Mode
In Random mode, the RPLS740B/RPLS741B has no specific times to turn the lights on or
off. This mode is designed to give the impression the house is occupied during your
absence. It is similar to the Automatic mode except there is no fixed program. The
programs are automatically set to different times by the RPLS740B/RPLS741B every day.
The
off. This mode is designed to give the impression the house is occupied during your
absence. It is similar to the Automatic mode except there is no fixed program. The
programs are automatically set to different times by the RPLS740B/RPLS741B every day.
The
icon appears when the switch is in Random mode.
The first “On” program occurs at sunset. Each “On” program lasts between 1 hour and 1
hour and 30 minutes; each “Off” program lasts between 15 and 30 minutes. The last “Off”
program occurs between 10:30 pm and midnight.
hour and 30 minutes; each “Off” program lasts between 15 and 30 minutes. The last “Off”
program occurs between 10:30 pm and midnight.
5.1.4 Temporary Override
When the RPLS740B/RPLS741B is in Automatic or Random mode, you can press the main button at any
time to override the default state for the current program. The lights will turn off if they are on and vice versa.
The icon (On or Off) of the new state flashes to indicate that the state is temporary. The new state is
maintained until you press the main button again or till the next “On” or “Off” program.
time to override the default state for the current program. The lights will turn off if they are on and vice versa.
The icon (On or Off) of the new state flashes to indicate that the state is temporary. The new state is
maintained until you press the main button again or till the next “On” or “Off” program.
5.2
Time Menu
The time display flashes on the screen when the time has not yet been set or after a 4-hour power outage.
Use the Time menu to select the time format (12-hour or 24-hour) and to set the clock and date.
NOTE: The date is used to determine the sunset and sunrise times.
Use the Time menu to select the time format (12-hour or 24-hour) and to set the clock and date.
NOTE: The date is used to determine the sunset and sunrise times.
5.3
Configuration Menu
(Conf)
Use the Configuration menu to set the following parameters (see sections 5.3.1 to 5.3.4).
5.3.1 Backlight mode (SCRN)
The screen is lit at high intensity for 8 seconds when you press any button. The rest of the time, depending
on the backlight mode selected, the screen behaves as follows:
Scrn Off: The screen is not lit.
Scrn On HI: The screen is lit at high intensity.
Scrn On LO: The screen is lit at low intensity (default mode).
on the backlight mode selected, the screen behaves as follows:
Scrn Off: The screen is not lit.
Scrn On HI: The screen is lit at high intensity.
Scrn On LO: The screen is lit at low intensity (default mode).
5.3.2 Automatic Daylight Savings Time Changeover (DLS)
When automatic daylight savings time changeover is on (DLS On), the RPLS740B/RPLS741B changes to
daylight savings time (summer time) at 2:00 am on the second Sunday of March and changes back to
normal time (winter time) at 2:00 am on the first Sunday of November. This function is enabled (DLS On) by
default.
daylight savings time (summer time) at 2:00 am on the second Sunday of March and changes back to
normal time (winter time) at 2:00 am on the first Sunday of November. This function is enabled (DLS On) by
default.
5.3.3 Latitude and Longitude Coordinates (LAT and LONG)
The coordinates are used to turn the lights on at sunset and off at sunrise. The latitude is set to +45 and lon-
gitude to -75 by default. These settings provide approximate sunset and sunrise times for most North Ameri-
can cities. To obtain your city’s coordinates (or those of a nearby city), see the coordinates table. You can
gitude to -75 by default. These settings provide approximate sunset and sunrise times for most North Ameri-
can cities. To obtain your city’s coordinates (or those of a nearby city), see the coordinates table. You can
Applications
1.
Load types
Maximum load
Examples
Lights and resistive
loads (except tungsten)
loads (except tungsten)
1800 W
(15 A @ 120 V)
(15 A @ 120 V)
•
fluorescent lights
•
compact fluorescent lights (CFL)
•
electronic ballasts
•
sodium lamps
•
block heaters
Tungsten lights
1440 W
(12 A @ 120 V)
(12 A @ 120 V)
•
incandescent lights
•
halogen lights
Motors
3/4 hp
•
pool filter pumps
•
fans
Installation
2.
NOTE:
This switch cannot be used if there is no neutral wire
(white wires joint together) inside the electrical box.
(white wires joint together) inside the electrical box.
Quick Start-up
3.
Set the time and date before using the timer for the first time.
Operation
4.
120
VAC
VAC
black
white
black
white
black (LINE)
white (NEUTRAL)
blue (LOAD)
The icon indicates the current
program has been activated at sunset.
The
program has been activated at sunset.
The
icon indicates the current
program has been activated at sunrise.
The LED illuminates when the load state
is on.
is on.
Briefly press this button to turn the
lights on or off. See “Temporary
Override” in Section 5.1.4.
Press for 3 seconds to enter the
setup menus.
lights on or off. See “Temporary
Override” in Section 5.1.4.
Press for 3 seconds to enter the
setup menus.
Indicates the mode of
operation (see Section 5.1)
operation (see Section 5.1)
Indicates the current program
Indicates the load on/off state
Indicates the time and day
Honeywell Econoswitch 7 Day User Manual Free
Press this button to display today’s sunrise time.
Press this button to display today’s sunset time.
Press this button to display today’s sunset time.
Setup Menus
5.
Press the main button for 3 seconds to enter the setup menus. Refer to
the menu flowchart sheet on how to navigate the menus.
the menu flowchart sheet on how to navigate the menus.
(3 sec.)
RPLS740B/RPLS741B
User guide
7-day Solar Programmable Wall Switch
69-2455EFS-01_400-071-003-A (TI071_RPLS740B) USA.book Page 1 Tuesday, May 18, 2010 10:49 AM
Advertising
Honeywell Econoswitch 7 Day User Manual Instructions
This manual is related to the following products:
Popular Brands
Popular manuals
Honeywell Econoswitch 7 Day User Manual Download
HONEYWELL Security & Custom Electronics 149 Eileen Way Syosset NY, 11791
Honeywell Econoswitch 7 Day User Manual Online
Architect and Engineer Specification for: IS25100TC Long Range PIR
DESCRIPTION: Document – Architects/Engineer Specification Model –IS25100TC Product Description – PIR Intrusion Detector Note – Words/statements within square brackets [] may be included when appropriate, or when selection is required. OVERVIEW: The Intrusion Detector[s] shall operate on the Verified Intrusion principle using Passive Infrared (PIR), and shall be listed by Underwriter’s Laboratories, Inc (cULus), SIA PIR-01 False Alarm Immunity standard, CE, EN50131-1 Grade 2 and Environmental Class II. INTERFACE AND ENCLOSURE: Each detector shall provide the detection, signal processing, alarm relay, and operating power circuitry in the same enclosure; and shall provide an alarm relay actuation upon the detection of an intruder moving into or through its protection pattern. The enclosure should be ready for surface and/or corner mounting, and shall be capable of mounting to a compatible Wall or Ceiling mounting bracket without modification. Each detector shall feature a single piece electronics board. The board shall have a snap fit into the rear housing. The rear housing shall be secured to the front housing with a snap fit and an optional screw. The enclosure should have a large rear wiring channel, shall include easy wiring knockouts, and shall provide wire strain relief points.
DESCRIPTION: Document – Architects/Engineer Specification Model –IS25100TC Product Description – PIR Intrusion Detector Note – Words/statements within square brackets [] may be included when appropriate, or when selection is required. OVERVIEW: The Intrusion Detector[s] shall operate on the Verified Intrusion principle using Passive Infrared (PIR), and shall be listed by Underwriter’s Laboratories, Inc (cULus), SIA PIR-01 False Alarm Immunity standard, CE, EN50131-1 Grade 2 and Environmental Class II. INTERFACE AND ENCLOSURE: Each detector shall provide the detection, signal processing, alarm relay, and operating power circuitry in the same enclosure; and shall provide an alarm relay actuation upon the detection of an intruder moving into or through its protection pattern. The enclosure should be ready for surface and/or corner mounting, and shall be capable of mounting to a compatible Wall or Ceiling mounting bracket without modification. Each detector shall feature a single piece electronics board. The board shall have a snap fit into the rear housing. The rear housing shall be secured to the front housing with a snap fit and an optional screw. The enclosure should have a large rear wiring channel, shall include easy wiring knockouts, and shall provide wire strain relief points.
Honeywell Econoswitch 7 Day User Manual Pdf
LED OPERATION: Each detector shall incorporate a single, Red LED to indicate the operating conditions. Red LED illuminated for 3 seconds shall indicate an alarm condition. Red LED not illuminated shall indicate a non-alarm condition. The Red LED blinking fast shall indicate a trouble condition. During initial power up, the Red LED shall blink slowly for up to 3 minutes while the circuits stabilize. The LED indicator shall be optional; it shall be capable of being field disabled using the On/off dip switch, or remotely from the control panel. Even when the LED is disabled, the LED shall stay enabled for 10 minutes after power up and/or for 10 minutes after the LED dip switch is toggled On to Off, to allow the installer or site manager to walk test the pattern. POWER REQUIREMENTS AND CURRENT CONSUMPTIONS: The detector[s] shall be capable of operating from a DC power source rated within the range of 8.5 to 15.4 VDC. The detector[s] current draw shall be 21 mA nominal, and 25 mA maximum at 12 VDC. The detector[s] shall withstand AC ripple from 50 to 120 Hz, 3 V peak-topeak at nominal 12 VDC. ALARM OPERATION: A condition of alarm shall occur when the PIR alarm conditions are met. The Detectable speed shall be 1~10 ft/sec. (0.2~3m/sec.). The alarm period shall be approximately 3.0 +/- 0.5 seconds. The alarm output shall be capable of handling 24 VDC, 30 mA max. The detector shall have 4 sensitivity settings selectable via dip switch. The sensitivity settings shall include Lowest, Low, Medium and High for times when the detector is installed in a hostile area, and times when greater sensitivity is required. Each detector shall signal the condition of alarm using a Normally Closed or Normally Open Relay with 45o terminal strip connections. The 45o terminal strip allows easier installation and the ability to inspect the wiring connection for a more reliable operation. The detector[s] shall also contain front cover and rear cover/wall removal tamper switches that shall open when the cover is removed, or the device is removed from the wall. To accomplish PIR detection, each detector shall contain a sealed Pyro-Electric sensor peaked for the detection of near-infrared energy
in the 10 micron region. The sealed area shall be black in color, providing enhanced immunity to false triggers caused by bright lights, and shall provide White light immunity to 6500 Lux minimum. The detector[s] shall use a solid state relay to transmit the alarm condition. The solid state relay is quiet in operation, for use in any environment where discretion or high security is a premium. The solid state relay can not be compromised with a magnet, for use in high security installations.
SENSOR STABILITY AND PERFORMANCE: The PIR detection shall use a balanced Dual Opposed Element detector to guard against unwanted alarms caused by changes in infrared energy not associated with motion. To guard against false activations caused by RF interference, the detector shall incorporate RFI protection. No alarm shall occur at 30 V/m within the range of 10-1000 MHz. A dual slope temperature compensation circuit shall also increase detection capability under high temperature conditions where the background temperature is similar to that of the human body. ENVIRONMENTAL CONDITIONS: The detector[s] shall be rated to operate within the temperature range of [14o Fahrenheit to 131 o Fahrenheit][minus10o Celsius to 55 o Celsius]. The detector[s] shall tolerate an environmental humidity rate of 5% to 95% maximum, non condensing. No false alarm shall occur within these operating conditions. OPTICS: The detector[s] shall use Fresnel lenses, and the optics chamber shall be sealed to eliminate the chance of a false alarm due to drafts or small insects. SELF TEST: The detector shall incorporate self tests of the PIR channel as well as the temperature compensation components to ensure proper circuit operation. The self test routine should run on power up and routinely
during operation. If the PIR self test fails, the alarm relay shall latch open (in alarm) and the LED shall blink fast. If a valid PIR signal is subsequently seen, the trouble will automatically clear itself and the detector will return to normal operation. If the temperature compensation self test fails, the detector will default to its room temperature settings and flash the Red LED fast, and on the next alarm condition, the detector will latch the alarm relay open (in alarm). LENS AND DETECTION PATTERNS: Each detector shall contain a front mounted hard and durable Fresnel lens that shall focus the received infrared energy onto the sensor. The Fresnel lens shall be designed to maintain Uniform Sensitivity Optics throughout the protection pattern, providing even coverage and detect ability throughout the coverage pattern, helping to detect an intruder at the edge of the protected area as easily as directly in front of the sensor. The sensor and module combined shall construct a Long Range detection field 100 feet x 20 feet (30m x 6m), or 11.5o wide, with 16 zones of detection (6 tiers, 2 zones each, plus 4 look down zones). The detector shall incorporate a selectable look down coverage pattern, which covers the area directly beneath the detector. The look down pattern shall use a 2 element mirror to project a minimum of 4 fingers in the area directly beneath the detector. The look down zones shall be optional, so that an installer can disable them in installations with pets, rodents or other animals that can get directly beneath the detector. MOUNTING HEIGHT: The detector[s] shall be capable of mounting at a height from 7’6” to 9’ [2.3-2.7m] without any adjustments, thereby minimizing possible installation errors. PHYSICAL CHARACTERISTICS: The dimensional size of the detector shall be 4-3/8”H x 2-1/4”W x 11/2”D [11.2cm x 6.0 cm x 4.0 cm]. WEIGHT: The total weight of the unit shall be 3.3 oz. (90g).
MODELS: The Intrusion Detector shall be model IS25100TC (standard) with optional wall mount bracket SMB10, or tampered wall mount bracket SMB10T, or ceiling mount bracket SMB10C.